Steam Generator Maintenance Manual

1. The water tank should maintain sufficient water volume, the water pump should not be idling, and the exhaust needle valve should be opened to release the air when there is air resistance and no water.

2. If there is an abnormal noise or the water is suddenly cut off during the operation of the pump, it should be stopped immediately to find the cause.

3. Must be grounded reliably to ensure safe use.

4. The safety valve has been calibrated before leaving the factory, and the opening pressure should not be adjusted arbitrarily. The discharge port of the safety valve should be directed to an unoccupied place, or it should be connected with a pipe. To avoid scalding the body when the safety valve is opened.

5. When using, the water level in the liquid level gauge should be checked frequently.

6. The wiring of the water level probe and its surroundings should be kept dry and free of foreign objects to avoid short circuit.

7. The boiler should be kept clean and the surface should be scrubbed after each use.